Mr. Guo
Leave a message1、 Working principle
The AO-100 series ultrasonic flowmeter/ultrasonic calorimeter utilizes the principle of low voltage and multi pulse time difference, and adopts digital detection technology of dual balanced signal differential transmission and differential reception to measure the sound wave transmission time in the forward and reverse directions, and calculate the flow velocity based on the time difference. It has the characteristics of good stability, small zero drift, high measurement accuracy, wide range ratio, and strong anti-interference ability.
Doppler ultrasonic flowmeter brings you professional service,when the ultrasonic beam propagates in a liquid, the flow of the liquid will cause a slight change in propagation time, which is proportional to the flow velocity of the liquid. At zero flow rate, the time required for the two sensors to emit and receive sound waves is exactly the same (a technology that can actually measure zero flow rate); When the medium flows, the transmission time of sound waves in the upstream direction is greater than that in the downstream direction. The relationship conforms to the following expression:

Content | FEATURES | remarks |
measurement accuracy | FLOW METER/calorimeter: better than ± 1.0%; Water meter: better than ± 2.0%; Heat meter: meets EN1434 standard | Please refer to the product introduction for details |
Repeatability | Better than ± 0.2% or ± 0.5% | |
Flow direction | Positive and negative bidirectional measurement, capable of measuring positive, negative, and net cumulative amounts | |
flow rate range | 0~± 32m/s | |
Measurement medium | A single, uniform, and stable liquid that can transmit ultrasonic waves, such as water, sewage, seawater, alcohol, and various oils | |
Applicable pipes | Carbon steel, stainless steel, cast iron, cement, copper PVC、 Aluminum and other uniform and dense pipelines are allowed to have lining | External clamp sensors are not suitable for cement pipes |
Fluid temperature | ≤ 160℃ | Please refer to the product introduction for details |
Fluid turbidity | ≤ 10000ppm with low bubble content | |
Display | Display instantaneous flow rate, heat, flow rate, cumulative amount, signal status, etc. in full Chinese | |
output interface | 4-20mA、Relay、OCT、 RS232、 RS485 outputs are optional | |
Input Interface | 4-20m Aanalog input | |
Other functions | Day, month, and year accumulator; Power on/off management function; Self diagnostic function for work status | |
Communication protocol | MODBUS protocol, M-BUS protocol, and Australian Thai extension protocol |
2、 Integrated ultrasonic flowmeter
The AO-100Y integrated ultrasonic flowmeter is a pipe segment ultrasonic flowmeter developed using a low-power microcontroller. This product solves the problem of decreased measurement accuracy caused by errors in the installation process of external and plug-in sensors due to human or inaccurate pipeline parameters. It has high precision, wide range ratio, low cost, simple installation, low pressure loss, and no mechanical moving parts. The launch of this product has changed users' perception that ultrasonic flow meters can only be installed separately, and is the future direction of ultrasonic flow meter development.
1. Measurement accuracy: better than ± 1%
2. Measurement cycle: twice per second (500ms)
3. Working power supply: 24V or AC220V optional
4. Flow velocity range: 0-32m/s
5. Display: Local 2x10 Chinese character backlit display
6. Signal input: 1-channel 4-20mA analog input, accuracy of 0.1%, can input temperature, pressure and other signals
7. Signal output: 1-channel 4-20mA analog output with an accuracy of 0.1%
2-channel programmable OCT output
Timed printing output extension function
Universal Serial Expansion Bus RS232/RS485 dual interface
8. Connection method: flange type/union type (sanitary type) optional
9. Operation: 16 key touch keyboard
10. Data storage: Automatically record accumulated traffic and work logs for the first 128 days, first 64 months, and first 5 years
Automatically record the time and flow of the first 32 power outages
11. Power outage protection: Data will not be lost after 100000 hours of power outage
12. Medium temperature: -40 ℃~160 ℃
13. Protection level: IP65
14. Electrical interface: M20 × 1.5
15. High power consumption: 1.2W
3、 Flange mechanical dimension table
Nominal Diameter DN(mm) | Rated pressure (MPa) | External dimensions of π - shaped pipe section(mm) | Standard pipe section external dimensions(mm) | 法兰尺寸(mm) | |||||
L1 | H1 | L2 | H2 | D | D1 | D2 | N-Φ | ||
15 | 2.5 | 320 | 136 | 95 | 65 | 46 | 14×4 | ||
20 | 360 | 142 | 105 | 75 | 56 | 14×4 | |||
25 | 390 | 151 | 115 | 85 | 65 | 14×4 | |||
32 | 450 | 157 | 140 | 100 | 76 | 18×4 | |||
40 | 500 | 169 | 150 | 110 | 84 | 18×4 | |||
50 | 1.6 | 200 | 260 | 165 | 125 | 99 | 18×4 | ||
65 | 200 | 280 | 185 | 145 | 118 | 18×4 | |||
80 | 225 | 295 | 200 | 160 | 132 | 18×8 | |||
100 | 250 | 314 | 220 | 180 | 156 | 18×8 | |||
125 | 250 | 347 | 250 | 210 | 184 | 18×8 | |||
150 | 300 | 372 | 285 | 240 | 211 | 22×8 | |||
200 | 350 | 430 | 340 | 295 | 266 | 22×12 | |||
250 | 450 | 489 | 405 | 355 | 319 | 26×12 | |||
300 | 500 | 543 | 460 | 410 | 370 | 26×12 | |||
350 | 550 | 599 | 520 | 470 | 429 | 26×12 | |||
400 | 600 | 653 | 580 | 525 | 480 | 26×16 | |||
450 | 700 | 708 | 640 | 585 | 548 | 30×20 | |||
500 | 800 | 771 | 670 | 620 | 585 | 25×20 | |||
600 | 1000 | 884 | 780 | 725 | 685 | 30×20 | |||
700 | 1100 | 964 | 860 | 810 | 775 | 24×25 | |||
800 | 1200 | 1072 | 975 | 920 | 880 | 24×30 | |||
900 | 1300 | 1172 | 1075 | 1020 | 980 | 24×30 | |||
1000 | 1400 | 1287 | 1175 | 1120 | 1080 | 28×30 | |||
4、 Dimensions table for articulated (sanitary) machinery
Nominal Diameter DN(mm) | Rated pressure (MPa) | Flexible external dimensions | texture of material | |||
L | H | D | C | |||
25 | 4.0 | 300 | 282 | 51 | 19 | stainless steel |
40 | 300 | 300 | 74 | 23 | ||
50 | 300 | 310 | 84 | 24 | ||
65 | 350 | 330 | 100 | 28 | ||
80 | 400 | 345 | 114 | 30 | ||
100 | 450 | 365 | 128 | 31 | ||
5、 Battery powered type
The battery powered integrated ultrasonic flowmeter is an ultra-low power ultrasonic flowmeter that can work for a long time using a 3.6V lithium battery. It has the characteristics of high measurement accuracy, maintenance free, and no operation, and is particularly suitable for field or urban pipeline measurement.
1. Measurement accuracy better than ± 1%
2. Repeatability better than ± 0.2%
3. Measurement cycle of 1 second (1s)
4. Flow velocity range 0~32m/s
5. 3.6V lithium battery can work continuously for more than two years
6. Local 96 segment ultra-low power LCD display:
Doppler ultrasonic flowmeter brings you professional service,positive and negative cumulative quantities, instantaneous flow rate, flow velocity, cumulative working time, date, working status, and error codes
Battery level, ultrasonic signal strength and signal quality
7. 4-20mA analog output (two-wire system)
8. RS232 (electricity theft output), RS485 (requires an additional 5V) data output
9. MODBUS and Australian Thai Extended Communication Protocol
10. Measurable medium temperature range -40 ℃~160 ℃
11. Internal dual button, magnetic stick operation
12. Head up and top-down display options are available
13. Flange and union (sanitary) connection methods are optional
14. Protection level: IP68
15. Explosion proof grade: EXd Ⅱ CT6
16. Power consumption: DN100 pipe diameter with an average power consumption of 1.65mw
6、 Flange mechanical dimension table
Nominal Diameter DN(mm) | Rated pressure (MPa) | External dimensions of π - shaped pipe section(mm) | Standard pipe section external dimensions(mm) | Flange size(mm) | |||||
L1 | H1 | L2 | H2 | D | D1 | D2 | N-Φ | ||
15 | 2.5 | 320 | 132 | 95 | 65 | 46 | 14×4 | ||
20 | 360 | 138 | 105 | 75 | 56 | 14×4 | |||
25 | 390 | 147 | 115 | 85 | 65 | 14×4 | |||
32 | 450 | 153 | 140 | 100 | 76 | 18×4 | |||
40 | 500 | 165 | 150 | 110 | 84 | 18×4 | |||
50 | 1.6 | 200 | 234 | 165 | 125 | 99 | 18×4 | ||
65 | 200 | 254 | 185 | 145 | 118 | 18×4 | |||
80 | 225 | 268 | 200 | 160 | 132 | 18×8 | |||
100 | 250 | 287 | 220 | 180 | 156 | 18×8 | |||
125 | 250 | 315 | 250 | 210 | 184 | 18×8 | |||
150 | 300 | 345 | 285 | 240 | 211 | 22×8 | |||
200 | 350 | 403 | 340 | 295 | 266 | 22×12 | |||
250 | 450 | 462 | 405 | 355 | 319 | 26×12 | |||
300 | 500 | 516 | 460 | 410 | 370 | 26×12 | |||
350 | 550 | 572 | 520 | 470 | 429 | 26×12 | |||
400 | 600 | 626 | 580 | 525 | 480 | 26×16 | |||
450 | 700 | 682 | 640 | 585 | 548 | 30×20 | |||
500 | 800 | 745 | 670 | 620 | 585 | 25×20 | |||
600 | 1000 | 858 | 780 | 725 | 685 | 30×20 | |||
700 | 1100 | 938 | 860 | 810 | 775 | 24×25 | |||
800 | 1200 | 1046 | 975 | 920 | 880 | 24×30 | |||
900 | 1300 | 1146 | 1075 | 1020 | 980 | 24×30 | |||
1000 | 1400 | 1261 | 1175 | 1120 | 1080 | 28×30 | |||
7、 Dimensions table for articulated (sanitary) machinery
Nominal Diameter DN(mm) | Rated pressure (MPa) | Flexible external dimensions | texture of material | |||
L | H | D | C | |||
25 | 4.0 | 300 | 178 | 51 | 19 | stainless steel |
40 | 300 | 196 | 74 | 23 | ||
50 | 300 | 206 | 84 | 24 | ||
65 | 350 | 226 | 100 | 28 | ||
80 | 400 | 241 | 114 | 30 | ||
100 | 450 | 261 | 128 | 31 | ||
Medium and large diameter pipe section:

Small caliber pipe segment type:

RELATED
RELATED
RELATED
RELATED
Company Address:
Building 5 and 11, Fuzhou IoT Industrial Park,
No. 12 Xingye West Road, Mawei District,
Fuzhou City, Fujian Province, China
Market Cooperation:
Manager Guo: +8613959146212
Copyright © 2025 Fujian Aotai Automation Equipment Co., Ltd
This website uses cookies to ensure you get the best experience on our website.
Comment
(0)