1、 Introduction to the performance of current input isolation safety barrier at the detection end


Provide isolated working power supply to transmitters in hazardous areas, while detecting the current in the circuit, and output current or voltage signals to the safe area through isolated transmission. The three terminal isolation of input, output, and power supply has the advantages of fast response, low power consumption, and good temperature characteristics.


2、 Technical parameters


Explosion proof mark: [Exia] Ⅱ C


Dangerous area allows input signal: current signal


Input impedance: approximately 80 Ω


Can output signals to the safe zone:


Current: 0 (4) mA~20mA; 0mA~10mA


Voltage: 0 (1) V to 5V;     0V~10V


Output load capacity:


0(4)mA~20mA:≤300Ω;


0mA~10mA:≤600Ω


0(1)V~5V:≥1MΩ;


0V~10V:≥2MΩ


Output ripple:<1mV


Distribution output voltage: open circuit voltage ≤ 24V


Voltage ≥ 15.5V at full load 20mA output


Isolation transmission accuracy: ± 0.2% F ∙ S (25 ℃± 2 ℃)


检测端电流输入安全栅


Temperature drift:<30ppm/℃


Response time: ≤ 0.2ms


Stability time: ≤ 2ms


Frequency response: 0Hz~300Hz (0Hz~5kHz can be customized)


Dielectric strength: ≥ 2500V AC (between input/output/power supply, leakage current 1mA, testing time 1min)


Insulation resistance: ≥ 100M Ω (between input/output/power supply)


Electromagnetic compatibility: EMC complies with IEC61000-4


Certification parameters of National Quality Supervision and Inspection Center for Instrumentation and Electrical Products (CQST): Um=250V AC/DC


10. Between terminals 11: Uo=5V


ⅡC         ⅡB          ⅡA


Co      70μF       700μF        700μF


9. Between terminals 11: Uo=26V, Io=87.6mA, Po=570mW


ⅡC          ⅡB          ⅡA


Co      0.069μF     0.539μF      1.82μF


Lo      3.2mH       9.6mH        25.6mH


Power supply: DC 18-32V (typical value 24V DC)


Power consumption: dual current source input, dual output 0.8W


Dual two/three wire input, dual output 1.8W


    


ONLINE MESSAGE

*Subject:
*E-mail:
Phone:
Company:
*Captcha:

RELATED PRODUCTS

Contact Us

Company Address:

Building 5 and 11, Fuzhou IoT Industrial Park, 

No. 12 Xingye West Road, Mawei District, 

Fuzhou City, Fujian Province, China

Market Cooperation:

Manager Guo: 13959146212


Copyright © 2025 Fujian Aotai Automation Equipment Co., Ltd

This website uses cookies to ensure you get the best experience on our website.

Accept Reject