Login | Register
产品中心
Home > Product > Rail mounted instruments > AO5019NPN detection terminal proximity switch input isolated safety barrier collector (two in two out)

AO5019NPN detection terminal proximity switch input isolated safety barrier collector (two in two out)

    AO5019NPN detection terminal proximity switch input isolated safety barrier collector (two in two out)

  • Category:
    Rail mounted instruments
  • Browse number:
    437
  • Release time:
    2025-05-07 17:27:54
  • Share:
  • INQUIRY

1、 Performance Overview


The NAMUR proximity switch signal in the hazardous area is isolated and converted to output to the safe area. The output mode is open circuit output with two collectors, and can also be selected for reverse phase.


The input terminal, output terminal, and power supply terminal are isolated from each other, and have the function of detecting line faults.


2、 Technical parameters


Explosion proof grade: [Exia] IIC


Dangerous area allows input signal: NAMUR proximity switch


Active signal trigger point: When the input signal is greater than 2.1m Α, it is indicated as "ON"


When the input signal is less than 1.2m Α, it is indicated as "OFF"


Short circuit current: about 8m Α Open circuit voltage: 8V


Line fault detection function (LFD): If the input current is less than 50 μ A, it is judged as input disconnection


Input current>6mA, judged as input short circuit


Output signal to safe zone: open collector


Current output: ≤ 40mA


External high input voltage: 40V DC


Short circuit current:<100mA


Input and output are reversed control settings: K1 and K3 are set to the ON side, and the input and output of the corresponding channel are reversed.


isolated safety barrier collector


K1 and K3 are set as side 1, and the input and output of the corresponding channels on side 3 are in phase.


K2 and K4 are set to the ON side without LFD function.


K2 and K4 are set to 2 sides, with LFD indicator function on 4 sides.


Switching frequency: ≤ 5kHz


Dielectric strength: ≥ 2500V AC (between input/output/power supply, leakage current 1mA, testing time 1min)


Insulation resistance: ≥ 100M Ω (between input/output/power supply)


Electromagnetic compatibility: EMC complies with IEC61000-4


Certification parameters of National Quality Supervision and Inspection Center for Instrumentation and Electrical Products (CQST): Um=250V AC/DC


9. Between 10 terminals, between 11 and 12 terminals: Uo=10.5V, Io=13mA, Po=34mW


ⅡC           ⅡB           ⅡA


Co        1.6μF         11.7μF       52.5μF


Lo        147mH         441mH        1000mH


Power supply: DC 18V~32V (typical value 24V DC)


Power consumption: DC 24V power supply, two collector open circuit outputs 1.0W


Usage environment


Working environment temperature: -20 ℃ to+60 ℃


Allowable relative humidity at work: 10% RH to 90% RH (40 ℃)


Allowable atmospheric pressure during work: 80kPa~106kPa


Allowable ambient temperature during storage and transportation: -40 ℃ to+80 ℃


    


ONLINE MESSAGE

*Subject:
*E-mail:
Phone:
Company:
*Captcha:

RELATED PRODUCTS

Contact Us

Company Address:

Building 5 and 11, Fuzhou IoT Industrial Park, 

No. 12 Xingye West Road, Mawei District, 

Fuzhou City, Fujian Province, China

Market Cooperation:

Manager Guo: 13959146212


Copyright © 2025 Fujian Aotai Automation Equipment Co., Ltd

This website uses cookies to ensure you get the best experience on our website.

Accept Reject